12 volt DC input, Pure Sine Wave 120 volt 60 Hz AC output , 50 Amp transfer switch, 80 Amp charger for main battery , and 1 Amp charger for start battery
Victron Energy PMP122200100 MultiPlus 12/2000/80-50 120V VE.Bus (NEW MODEL)
The new model of the MultiPlus 12/2000 has a new case design and a lower price but the internal design is otherwise unchanged.
12 volt DC input
Pure Sine Wave 120 volt 60 Hz AC output
50 Amp transfer switch
80 Amp charger for main battery , and 1 Amp charger for start battery
Dims 20" high x 9.3" wide x 5.8" deep
Shipping available within the US
MultiPlus 12/2000/80
MultiPlus 24/2000/50
MultiPlus 48/2000/25
PowerControl / PowerAssist
Yes
Transfer switch
50A
INVERTER
Input voltage range
Output
Cont. output power at 25°C (3)
2000VA
Cont. output power at 25°C
1600W
Cont. output power at 40°C
1400W
Cont. output power at 65°C
1000W
Peak power
3500W
Maximum efficiency in %
93 / 94 / 95
Zero-load power
10 / 11 / 11W
Zero-load power search mode
3 / 4 / 4W
CHARGER
AC Input
Input voltage range: 95-140 VAC
Input frequency: 45 – 65 Hz
Charge voltage 'absorption'
14,4 / 28,8 / 57,6V
Charge voltage 'float'
13,8 / 27,6 / 55,2V
Storage mode
13,2 / 26,4 /52,8V
Charge current house battery (4)
80 / 50 / 25A
Charge current starter battery
1 A (12V and 24V models only)
Battery temperature sensor
Yes
GENERAL
Programmable relay (5)
Yes
Protection (2)
a – g
Common Characteristics
Operating temp. range: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics
Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
Battery-connection
M8 bolts
230V AC-connection
Screw terminals 13 mm² (6 AWG)
Weight
15,2kg
Dimensions (h x w x d)
506 x 234 x 146 mm
STANDARDS
Safety
EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission / Immunity
EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles
ECE R10-4
9,5 – 17V
19 – 33V
38– 66V
Output voltage: 120VAC ± 2%
Frequency: 60Hz ± 0,1% (1)
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for:
general alarm, DC under voltage or generator start/stop signal function
AC rating: 230V/4A
DC rating: 4A up to 35VDC, 1A up to 60VDC